Example:
The small pointer is between ‘.1’ and ‘.2’ or between ‘.6’ and
‘.7’=0.1” or 0.6”
The large pointer is close to line ‘21’ of black digit=0.021”
So the reading is 0.1”+0.021”=0.121”
Or 0.6”+0.021”=0.621”
3. Reading 5604:
- Dial face has dual directional graduation of 0.01mm.
- Revolution counter is graduated in 1mm. Once full revolution
of large pointer is one increment of revolution counter.
Example:
The small pointer is between ‘1’ and ‘2’=1mm
So the reading is 1mm+0.14mm=1.14mm
4. Setting up:
- 5603 has 3/8” diameter shank and ¼” diameter mounting hole,
5604 has 8mm diameter mounting hole. The shank or the
mounting hole can be fixed on magnetic bases.
- Position measuring tip against the piece to be measured so
that it is depressed slightly. Plunger should be perpendicular
to the surface being measured.
- Loosen bezel locking screw and rotate bezel till large pointer
points at zero. Tighten bezel locking screw to lock the bezel at
its new position.
5. Move the left tolerance index to the position of lower limit and the
right tolerance index to the position of upper limit, It can be found
easily if the large pointer is our of limit.
6. Measuring tip should be carefully prevented from being hit. Do not
operate abruptly, drop or strike dial indicators